Sherif Moursi and Mahmoud R. El-Sakka, "Active Contours
Initialization for Ultrasound Carotid Artery Images", ACS/IEEE
International Conference on Computer Systems and Applications,
AICCSA'2008, pp. 629-636, April 2008, Doha, Qatar.
Abstract
One of the major issues of active contouring methods is their
sensitivity to the initial contour that is provided by the
user. Unless it is drawn close enough to the actual contour,
it may lead to unsatisfactory results. Thus, most active
contour algorithms require considerable user interaction to
provide a good initial contour.
In this paper we present an efficient and fast rule-based
algorithm for generating a good carotid artery initial contour
from ultrasound images. Our algorithm reduces user
interaction, as a user is only required to place a seed point
inside the region of interest.
Sensitivity, precision rate, and overlap ratio have been used
to assess the amount of correlation between manually segmented
lumens by an experienced clinician and by our algorithm, where
the obtained 95% confidence interval of the mean value of
these measures over all test cases are: [78.32% ± 1.98],
[91.77% ± 1.96], and [72.68% ± 1.90], respectively.
Furthermore, the output of our proposed scheme can be used as
an input to any active contour algorithm to produce even
better results